2019
DOI: 10.1109/tmi.2019.2910871
|View full text |Cite
|
Sign up to set email alerts
|

SNR-Adaptive OCT Angiography Enabled by Statistical Characterization of Intensity and Decorrelation With Multi-Variate Time Series Model

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
24
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 33 publications
(24 citation statements)
references
References 38 publications
0
24
0
Order By: Relevance
“…These signals are observed in the inner choroidal layers in healthy eyes, and they may change in the lesions from a variety of chorioretinal diseases. 14 , 15 In the two cases described herein, the decorrelation signals were not observed inside the MCM. We raise two conjectures for the absence of decorrelation signals inside the abnormal choroidal vessel.…”
Section: Discussionmentioning
confidence: 68%
“…These signals are observed in the inner choroidal layers in healthy eyes, and they may change in the lesions from a variety of chorioretinal diseases. 14 , 15 In the two cases described herein, the decorrelation signals were not observed inside the MCM. We raise two conjectures for the absence of decorrelation signals inside the abnormal choroidal vessel.…”
Section: Discussionmentioning
confidence: 68%
“…OCTA is the functional extension of OCT to obtain blood vessels map without contrast agents. [70][71][72] Because our electrode is transparent, OCTA image showed the vessels beneath the electrode without any obstruction (Figure 5b). The region of interest for detecting the relative change in deoxy-Hb in blood vessels was selected near the microelectrode (Figure S26, Supporting Information).…”
Section: Resultsmentioning
confidence: 97%
“…2(a) and 2(b) to emphasize blood flow by mathematically analyzing the temporal dynamics induced by moving red blood cells (RBCs). 49 The cross-sectional angiogram was binarized to generate an avascular mask for each frame in one trial, where the vessel area was set to be zero and the surrounding tissue was one. The intersection of all single-frame avascular masks was taken as the final vascular mask, as showed in Fig.…”
Section: Discussionmentioning
confidence: 99%
“…To see the hemodynamic response to INS, the RBCs-induced interframe decorrelation value of OCTA was used as the velocity index of blood flow. 49 OISI and OCT were spatially coregistered using pial blood vessels as rough landmarks and shifting the ROI until Pearson's correlation coefficient of OISI image (540-nm green LED illumination) and projection view of OCT reached the maximum. Accordingly, the functional OISI signals were calculated in a similar way yet without masks.…”
Section: Discussionmentioning
confidence: 99%