2010
DOI: 10.1088/0031-9155/56/2/008
|View full text |Cite
|
Sign up to set email alerts
|

The accuracy of dose calculations by anisotropic analytical algorithms for stereotactic radiotherapy in nasopharyngeal carcinoma

Abstract: Nasopharyngeal tumors are commonly treated with intensity-modulated radiotherapy techniques. For photon dose calculations, problems related to loss of lateral electronic equilibrium exist when small fields are used. The anisotropic analytical algorithm (AAA) implemented in Varian Eclipse was developed to replace the pencil beam convolution (PBC) algorithm for more accurate dose prediction in an inhomogeneous medium. The purpose of this study was to investigate the accuracy of the AAA for predicting interface d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
0

Year Published

2011
2011
2020
2020

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 28 publications
(17 citation statements)
references
References 19 publications
0
17
0
Order By: Relevance
“…2 A number of studies have shown the limitation of photon dose calculation algorithms such as analytical anisotropic algorithm (AAA), collapsed cone convolution (CCC) algorithm, and pencil beam convolution (PBC) algorithm when complex geometry with inhomogeneity is involved along the photon beam path. [3][4][5][6][7][8][9][10][11][12] Both the AAA and CCC are based on the superposition/convolution method, which calculates the dose by superposition of dose kernels of primary and scatter components that are derived from the Monte Carlo (MC). The tissue inhomogeneity correction in superposition/convolution method such as in the AAA is done both in the beamlet direction and lateral directions.…”
Section: Introductionmentioning
confidence: 99%
“…2 A number of studies have shown the limitation of photon dose calculation algorithms such as analytical anisotropic algorithm (AAA), collapsed cone convolution (CCC) algorithm, and pencil beam convolution (PBC) algorithm when complex geometry with inhomogeneity is involved along the photon beam path. [3][4][5][6][7][8][9][10][11][12] Both the AAA and CCC are based on the superposition/convolution method, which calculates the dose by superposition of dose kernels of primary and scatter components that are derived from the Monte Carlo (MC). The tissue inhomogeneity correction in superposition/convolution method such as in the AAA is done both in the beamlet direction and lateral directions.…”
Section: Introductionmentioning
confidence: 99%
“…[13] Recently, authors in a paper on the accuracy of dose calculations by the AAA algorithm for stereotactic radiotherapy in nasopharyngeal carcinoma concluded that the results from the AAA were much better than those calculated by the PBC algorithm. [14]…”
Section: Introductionmentioning
confidence: 99%
“…In the previous study reported by Kan et al. (25) , there was also low gamma passing rates in the air-tissue interface.…”
Section: Discussionmentioning
confidence: 65%