Dual energy basis decomposition techniques apply to single projection radiographic imaging. The high and low energy images are non-linearly transformed to generate two energy-independent images characterizing the integrated Compton/photoelectric attenuation components. Characteristic linear combinations of these two basis images identify unknown materials, cancel known materials, and generate synthesized monoenergetic images. The problems of intervening materials and material displacement are solved in general for a wide class of clinical imaging tasks. The basis projection angle identifies one from a family of energy selective imaging tasks, and such performance measures as the contrast enhancement factor (CEF) and signal to noise ratio (SNR) are expressed as functions of this angle. Algorithms for the decomposition of high and low energy measurements are compared and experimental images are included.
Information contained in the x-ray energy spectrum can be used to produce selective radiographic images of bone or soft tissue. A method has been devised to separate bone and soft tissue based upon differences in photoelectric absorption and Compton scattering using an appropriate combination of images obtained with radiographic exposures at 70 KVP and 140 KVP. Since photoelectric absorption is highly dependent upon atomic number, high atomic number materials such as calcium can be easily separated from water density substances. Using a prototype system for line-scanned radiography, selective subtraction of bone or soft-tissue has been implemented. Because this method uses a conventional broad-spectrum x-ray source, it was necessary to develop a nonlinear polynomial approximation to estimate tissue and bone thickness. The model was verified with phantom studies using water and aluminum. The application of this dual-energy bone and soft-tissue separation to chest radiography is demonstrated. This method allows accurate estimation of tissue and bone thickness and should find application to chest radiography for improved lesion detection and for bone mineral assessment.
The subharmonic emission from insonified contrast microbubbles was used to create a new imaging modality called Subharmonic Imaging. The subharmonic response of contrast microbubbles to ultrasound pulses was first investigated for determining adequate acoustic transmit parameters. Subharmonic A-lines and gray scale images were then obtained using a laboratory pulse-echo system in vitro and a modified ultrasound scanner in vivo. Excellent suppression of all backscattered signals other than from contrast microbubbles was achieved for subharmonic A-lines in vitro while further optimization is required for in vivo gray scale subharmonic images.
Our group has proposed the concept of subharmonic aided pressure estimation (SHAPE) utilizing microbubble-based ultrasound contrast agent signals for the noninvasive estimation of hydrostatic blood pressures. An experimental system for in vitro SHAPE was constructed based on two single-element transducers assembled confocally at a 60 degree angle to each other. Changes in the first, second and subharmonic amplitudes of five different ultrasound contrast agents were measured in vitro at static hydrostatic pressures from 0-186 mmHg, acoustic pressures from 0.35-0.60 MPa peak-to-peak and frequencies of 2.5-6.6 MHz. The most sensitive agent and optimal parameters for SHAPE were determined using linear regression analysis and implemented on a Logiq 9 scanner (GE Healthcare, Milwaukee, WI). This implementation of SHAPE was then tested under dynamic-flow conditions and compared to pressure-catheter measurements. Over the pressure range studied, the first and second harmonic amplitudes reduced approximately 2 dB for all contrast agents. Over the same pressure range, the subharmonic amplitudes decreased by 9-14 dB and excellent linear regressions were achieved with the hydrostatic pressure variations (r = 0.98, p < 0.001). Optimal sensitivity was achieved at a transmit frequency of 2.5 MHz and acoustic pressure of 0.35 MPa using Sonazoid (GE Healthcare, Oslo, Norway). A Logiq 9 scanner was modified to implement SHAPE on a convex transducer with a frequency range from 1.5-4.5 MHz and acoustic pressures from 0-3.34 MPa. Results matched the pressure catheter (r2 = 0.87). In conclusion, subharmonic contrast signals are a good indicator of hydrostatic pressure. Out of the five ultrasound contrast agents tested, Sonazoid was the most sensitive for subharmonic pressure estimation. Real-time SHAPE has been implemented on a commercial scanner and offers the possibility of allowing pressures in the heart and elsewhere to be obtained noninvasively.
SHI appears to improve the diagnosis of breast cancer relative to conventional US and mammography, albeit on the basis of results in a very limited number of subjects.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.