Attenuation and respiratory motion correction should be applied to reduce artifacts before reporting on small defects in deep breathing conditions. Artifacts due to misalignment between CT and SPECT scans do not affect defect detection in normal breathing when the LV is co-registered in SPECT and CT images prior to AC.
This paper presents an algorithm for improving the interpolation accuracy in turning operations. The parts considered are formed by revolving a free-form profile which is implemented in terms of Bézier formulation around a center linear axis. The demand for the manufacturing of such geometric shapes is frequently met in parts produced by casting and forging methods. The method employs a computer numerical control (CNC) turning machine and is based on the locus tracing concept. The algorithm described utilizes a real-time CNC interpolator providing the highest possible accuracy of which the turning machine is capable. The whole machining task can be programmed as a canned cycle, essentially extending the feature generating capabilities of the existing G70/ G73 CNC turning fixed cycles.
Post-surgical I-123 and I-131 SPECT/CT imaging can provide information on the presence and sizes of thyroid remnants and/or metastasis for an accurate re-staging of disease to apply an individualized radioiodine therapy. The purpose of this study was to develop and validate a neck–thyroid phantom with small sizes of thyroid remnants to be utilized for the optimization of post-surgical SPECT/CT imaging. 3D printing and molding techniques were used to develop the hollow human-shaped and -sized phantom which enclosed the trachea, esophagus, cervical spine, clavicle, and multiple detachable sections with different sizes of thyroid remnant in clinically relevant positions. CT images were acquired to evaluate the morphology of the phantom and the sizes of remnants. Triple-energy window scattered and attenuation corrected SPECT images were acquired for this phantom and for a modified RS-542 commercial solid neck–thyroid phantom. The response and sensitivity of the SPECT modality for different administered I-123 and I-131 activities within the equal-size remnants of both phantoms were calculated. When we compared the phantoms, using the same radiopharmaceutical and similar activities, we found that the measured sensitivities were comparable. In all cases, the I-123 counting rate was higher than the I-131 one. This phantom with capabilities to insert different small sizes of remnants and simulate different background-to-remnants activity ratios can be utilized to evaluate postsurgical thyroid SPECT/CT imaging procedures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.