With typical reported workloads, radiation doses to eye lenses may exceed the threshold for deterministic effects (ie, lens opacities or cataracts) after several years of work if radiation protection tools are not used.
This report describes occupational radiation doses of interventional cardiologists over 15 years and assesses action undertaken to optimize radiation protection. Personal dosimetry records of nine staff cardiologists and eight interventional cardiology fellows were recorded using personal dosemeters worn over and under their lead aprons. The hospital in which this study was conducted currently performs 5000 cardiology procedures per year. The hospital has improved its facilities since 1989, when it had two old-fashioned theatres, to include four rooms with more advanced and safer equipment. Intensive radiation protection training was also implemented since 1989. Initially, some individual dose values in the range of 100-300 mSv month(-1), which risked exceeding some regulatory dose limits, were measured over the lead apron. Several doses in the range of 5-11 mSv month(-1) were recorded under the apron (mean = 10.2 mSv year(-1)). During the last 5 years of the study, after the implementation of the radiation protection actions and a programme of patient-dose optimization, the mean dose under the apron was reduced to 1.2 mSv year(-1). Current mean occupational doses recorded under the lead apron are 14% of those recorded during 1989-1992 and those recorded over the apron are 14-fold less than those recorded during 1989-1992. The regulatory dose limits and the threshold for lens injuries might have been exceeded if radiation protection facilities had not been used systematically. The most effective actions involved in reducing the radiation risk were training in radiation protection, a programme of patient-dose reduction and the systematic use of radiation protection facilities, specifically ceiling-suspended protective screens.
The aim of this work has been to determine typical occupational dose levels in interventional radiology and cardiology installations and to relate doses to patient and occupational dosimetry through the dose-area product. An experimental correlation between environmental dosimetric records and dose-area products in the centres studied was established. The study covered a sample of 83 procedures performed by 10 specialists in six laboratories. The radiologists and cardiologists monitored wore nine thermoluminescent chips next to eyes, forehead, neck, hands, left shoulder, left forearm and left arm during each single procedure. In addition, direct reading electronic devices for environmental dosimetry were placed in the C-arm of the X-ray system, to estimate roughly the occupational radiation risk level. Typical shoulder doses derived from electronic dosimetry range between 300 and 500 muSv per procedure, assuming no lead protective screens were used. Using these values and patient dose-area data from two laboratories, averaged ratios of 84 and 120 muSv per 1000 cGy cm2 are obtained for cardiology procedures. Finally, occupational dose reductions of approximately 20% when using highly filtered X-ray beams with automatic tube potential (kV) reduction (available in some facilities), and by a factor of about three when using ceiling mounted screens, have been found.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.