This study investigates the potential of propolis-embedded zeolite nanocomposites for dental implant application. Propolis-embedded zeolite nanocomposites were fabricated by complexation of propolis and zeolites. Then, they were pelleted with Poly(L-lactide) (PLA)/poly(e-caprolactone) (PCL) polymer for the fabrication of a dental implant. The chemical properties of propolis were not changed during the fabrication of propolis-embedded zeolite nanocomposites in attenuated total reflection-fourier transform infra-red (ATR FT-IR) spectroscopy measurements. Propolis was continuously released from propolis-embedded zeolite nanocomposites over one month. PLA/PCL pellets containing propolis-embedded zeolite nanocomposites showed longer sustained release behavior compared to propolis-embedded zeolite nanocomposites. Propolis-embedded zeolite nanocomposite powder showed similar antibacterial activity against C. albicans in an agar plate and formed an inhibition zone as well as chlorohexidine (CHX) powder. Eluted propolis solution from PLA/PCL pellets also maintained antibacterial activity as well as CHX solution. Furthermore, eluted propolis solution from PLA/PCL pellets showed significant antibacterial efficacy against C. albicans, S. mutans and S. sobrinus. Dental implants fabricated from PLA/PCl polymer and propolis-embedded zeolite nanocomposites also have antibacterial efficacy and negligible cytotoxicity against normal cells. We suggest that PLA/PCl pellets containing propolis-embedded zeolite nanocomposites are promising candidates for dental implants.
VR and AR technology have gradually developed to the extent that they could help operators in the surgical field. In this study, we present a case of VR simulation for preoperative planning and AR navigation applied to orthognathic surgery. The average difference between the preplanned data and the post-operative results was 3.00 mm, on average, and the standard deviation was 1.44 mm. VR simulation could provide great advantages for 3D medical simulations, with accurate manipulation and immersiveness. AR navigation has great potential in medical application; its advantages include displaying real time augmented 3D models of patients. Moreover, it is easily applied in the surgical field, without complicated 3D simulations or 3D-printed surgical guides.
The development of a guided bone regeneration (GBR) membrane with non-mammalian fish collagen has the advantage of low risk for transmission of infectious diseases in tissue regeneration. In this work, a fish collagen/gellan gum and bone graft material (FC/GG-BGM) composite GBR membrane were fabricated through solution blending and casting procedures in a vacuum. The membranes were characterized using Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), scanning electron microscopy observation (SEM), and atomic force microscope (AFM) analyses. FT-IR results suggested that ionic interactions were formed between FC and GG both in composite powder and membranes. In vivo experiments showed that these FC/GG-BGM composite membranes could generate osteoblast minerals and promote loose bone calcification, thus accelerating bone regeneration. At 2 weeks, the defected site of rats treated with FC/GG-BGM membrane (0.377 ± 0.012 mm3) showed higher regeneration than that of rats treated with the bovine collagen membrane (0.290 ± 0.015 mm3) and control rats without membrane (0.160 ± 0.008 mm3). Compared with bovine collagen membrane, the FC/GG-BGM composite membrane displays better bone regeneration ability. Therefore, FC/GG-BGM composite membrane is suitable as a GBR membrane for bone regeneration.
The purpose of this study is to analyze the clinical results of the implant rehabilitation for a jaw reconstructed by the deep circumflex iliac artery (DCIA) flap. A total of 13 patients were included in this study from 2010 to 2020. Medical records were collected retrospectively and analyzed. The mandible was involved in 10 cases and the maxilla was in 3 cases. The average width of the DCIA flap was 8.6 mm, and the height was 20.65 mm. A total of 41 dental implants with a diameter of 3.9–5.0 mm and a length of 10.0–11.5 mm were placed at an average of 12.3 months after the reconstruction. The average follow-up period after delivering a permanent prosthesis was 15 months (range, 2 to 51 months) and the overall mean follow-up period was 48 months. In all, 3 implants of the total 41 implants were removed. The DCIA flap is the most suitable for reproducing the original contour of the original jawbone compared with the fibular flap. In addition, the height and width of the reconstructed bone is appropriate for implant placement, which is advantageous for the rehabilitation of oral function and aesthetics using the implant.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.