A total of 124 fecal specimens were collected from four deer farms in Zhengzhou City, China and examined for Cryptosporidium by Sheather's sugar flotation technique. Cryptosporidim oocysts were detected in two 1-year-old sika deer, and one of the two specimens was genotyped by sequence and phylogenetic analyses of the small subunit ribosomal RNA (rRNA) (18S rRNA), 70-kDa heat shock protein (HSP70), actin, and Cryptosporidium oocyst wall protein (COWP) genes. Results obtained suggested that the Cryptosporidium studied belonged to Cryptosporidium cervine genotype, although slight sequence differences were noticed at the three loci. The similarities between this isolate and other Cryptosporidium cervine genotype isolates were 99.1-99. 8%, 9.8%, 99.7%, and 100% at the 18S rRNA, HSP70, actin, and COWP loci, respectively. This study is the first report of Cryptosporidium infection in sika deer in China.
Articles you may be interested inNovel tapered macrogate structure for carbon nanotube based field emission display Architecture of field emission display based on a gate electrode of diabolo modeThe authors measured the residual gas spectrum of a field emission display ͑FED͒ with carbon nanotube ͑CNT͒ emitters and found that the main residual gases inside a sealed CNT FED, containing an evaporated Ba getter, are H 2 , CH 4 , CO, Ar, and CO 2 , all of which are typical residual gases of electronic vacuum tubes. Additionally they also measured the electron stimulated desorption of gases by operating their field emission devices.
The design of a micro chamber quadrupole mass spectrometer ͑MCQMS͒ having a small total volume of only 20 cm 3 , including Faraday cup ion detector and ion source, is described. This MCQMS can resist a vacuum baking temperature of 400-500°C. The quadrupole elements with a hyperbolic surface are made of a ceramic material and coated with a thin metal layer. The quadrupole mass filter has a field radius of 3 mm and a length of 100 mm. Prototypes of this new MCQMS can detect a minimum partial pressure of 10 −8 Pa, have a peak width of ⌬M = 1 at 10% peak height from mass number 1 to 60, and show an excellent long-term stability. The new MCQMS is intended to be used in residual gas analyses of electron devices during a mutual pumping and baking process.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.