This article describes a prenatal ultrasonographic finding of an infarcted intestinal volvulus. Ultrasonography showed polyhydramnios, multiple dilated intestinal loops, increased transverse abdominal area, and ascites. After cesarean section due to premature rupture of membranes and fetal distress, derotation of the infarcted volvulus caused postoperative thrombocytopenia, hyperkalemia, and acidosis and a subsequent resection was required. A high output of intestinal juice from the jejunostomy caused severe hypovolemia and electrolyte imbalance with resultant death. Increased transverse abdominal area caused by marked intestinal dilatation, ascites, fetal distress, and hydrops fetalis may suggest an infarcted intestinal volvulus.
ObjectivesThis study sought to investigate the clinical utility of aortic valve calcium score (AVCS) determined by using cardiac multislice computed tomography (MSCT).MethodsData of 1315 consecutive patients who underwent both conventional echocardiography and MSCT were reviewed. Degree of aortic stenosis (AS) was assessed according to mean pressure gradient (mPG) measured by echocardiography. Extent of coronary artery disease (CAD) derived by MSCT also was evaluated in 1173 patients who did not undergo prior coronary treatment. Both AVCS and coronary calcium score (CCS) were defined by Agatston units (AU) according to MSCT findings.ResultsA total of 613 of 1315 patients were defined as AVCS positive (mean, 100 AU [range, 31.0–380.0 AU]). AVCS showed significant correlations with mPG (Spearman's ρ = 0.81, p < 0.001), and CCS (ρ = 0.53, p < 0.001). Differential adequate cut-off values of AVCS were proved for predicting severe AS with mPG ≥ 40 mmHg (1596.5 AU; AUC, 0.88; sensitivity, 89.7%; specificity, 77.0%), and for predicting moderate AS with mPG ≥ 20 mmHg (886.5 AU; area under the curve [AUC], 0.91; sensitivity, 92.4%; specificity, 78.3%). Mean AVCS was higher with increased extent of CAD (none, 0 AU [range, 0–30 AU]; single vessel, 8.5 AU [range, 0–104 AU]; multivessel, 142 AU [range, 10–525 AU]; p < 0.001). The optimal cut-off value of AVCS for predicting multivessel disease was 49 AU (AUC, 0.77; sensitivity, 68.8%; specificity, 78.0%).ConclusionsAVCS might be a surrogate marker not only for AS grading but also for CAD progression. Therefore, routine AVCS assessment could be useful for risk stratification.
Recently, antegrade dissection re-entry (ADR) with re-entry device for chronic total occlusion (CTO) percutaneous coronary intervention (PCI) has evolved to become one of the pillar techniques of the hybrid algorithm. Although the success rate of the device is high, it could be improved. We sought to evaluate the current trends and issues associated with ADR in Japan and evaluate the potential of cardiac computed tomography angiography (CCTA) for ADR procedure. A total 48 patients with CTO suitable for ADR evaluated by baseline conventional angiography and CCTA were enrolled. Procedural success and technical success were evaluated as the primary and secondary observations. Furthermore, all puncture points were analyzed by CCTA. CT score at each punctured site depended on the location of plaque deposition (none; + 0, at isolated myocardial site; + 1, at epicardial site; + 2) and the presence of calcification (none; + 0, presence; + 1) was analyzed and calculated (score 0–3). Overall procedure success rate was 95.8%. Thirty-two cases were attempted with the ADR procedure and 25 cases of them were successful. The technical success rate was 78.1% and myocardial infarction or other major complications were not observed in any cases. CT score at 60 puncture sites in 32 cases were analyzed and the score at technical success points was significantly smaller compared to that at technical failure points (0.68 ± 1.09 vs 1.77 ± 1.09, p < 0.0001). CTO-PCI with Stingray device in Japan could achieve a high procedure success and technical success rate. Pre procedure cardiac CT evaluation might support ADR procedure for appropriate patient selection or puncture site selection.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.