The Management of Wageningen Marine Research is not responsible for resulting damage, as well as for damage resulting from the application of results or research obtained by Wageningen Marine Research, its clients or any claims related to the application of information found within its research. This report has been made on the request of the client and is wholly the client's property.
Abstract-A method was developed to isolate lipophilic compounds efficiently from small aliquots of blood plasma and test these for total dioxin-like toxic potency using recombinant rat (H4IIE) and mouse (Hepa1c1c7) hepatoma cell lines, containing the firefly (Photinus pyralis) luciferase gene under trans-activational control of the aryl hydrocarbon receptor (AhR). For this experiment, blood plasma was used originating from eider ducks (Somateria mollissima) that had been dosed with 3,3Ј,4,4Ј-tetrachlorobiphenyl (PCB-77) or with the technical PCB-mixture Clophen A50. For each sample the CALUX (chemical-activated luciferase expression) response of both the fat-containing organic extract and the fat-free, cleaned extract were compared with data from chemical analyses of these samples. The CALUX responses for the extracts were converted into so-called CALUX TEQs (TCDD equivalents), using a 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) standard curve. The CALUX TEQs in both fatty and cleaned extracts correlated significantly with PCB-77 or PCB-153 levels (depending on the dosage group) determined in blood plasma using gas chromatography-mass spectrometry (GC-MS). For PCB-77 a toxic equivalency factor (TEF) of 1.5 ϫ 10 Ϫ3 was calculated based on these correlations. In addition, PCB-118 and PCB-156 levels in abdominal fat (assessed with GC with electron capture detection) and hepatic ethoxyresorufin O-deethylase activities correlated well with the CALUX TEQs in both fatty and cleaned blood plasma extracts, suggesting the TEQ levels in blood offer a good measure for internal dose. Plasma cholesterol and triglyceride levels were determined as a measure of lipid content, in 10-l aliquots of blood plasma using enzymatic spectrophotometric determination. In conclusion, we have demonstrated that the CALUX assay is a rapid, sensitive assay for assessing the toxic potency of (mixtures of) AhR-active compounds in small aliquots of blood plasma. The limit of detection for the CALUX assay is currently less than 0.1 fmol (32 fg) TEQ, which corresponds with the amount of TEQs present in 0.1 to 1 ml of blood plasma in environmentally exposed species or man.
A method was developed to isolate lipophilic compounds efficiently from small aliquots of blood plasma and test these for total dioxin-like toxic potency using recombinant rat (H4IIE) and mouse (Hepa1c1c7) hepatoma cell lines, containing the firefly (Photinus pyralis) luciferase gene under trans-activational control of the aryl hydrocarbon receptor (AhR). For this experiment, blood plasma was used originating from eider ducks (Somateria mollissima) that had been dosed with 3,3Ј,4,4Ј-tetrachlorobiphenyl (PCB-77) or with the technical PCB-mixture Clophen A50. For each sample the CALUX (chemical-activated luciferase expression) response of both the fat-containing organic extract and the fat-free, cleaned extract were compared with data from chemical analyses of these samples. The CALUX responses for the extracts were converted into so-called CALUX TEQs (TCDD equivalents), using a 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) standard curve. The CALUX TEQs in both fatty and cleaned extracts correlated significantly with PCB-77 or PCB-153 levels (depending on the dosage group) determined in blood plasma using gas chromatography-mass spectrometry (GC-MS). For PCB-77 a toxic equivalency factor (TEF) of 1.5 ϫ 10 Ϫ3 was calculated based on these correlations. In addition, PCB-118 and PCB-156 levels in abdominal fat (assessed with GC with electron capture detection) and hepatic ethoxyresorufin O-deethylase activities correlated well with the CALUX TEQs in both fatty and cleaned blood plasma extracts, suggesting the TEQ levels in blood offer a good measure for internal dose. Plasma cholesterol and triglyceride levels were determined as a measure of lipid content, in 10-l aliquots of blood plasma using enzymatic spectrophotometric determination. In conclusion, we have demonstrated that the CALUX assay is a rapid, sensitive assay for assessing the toxic potency of (mixtures of) AhR-active compounds in small aliquots of blood plasma. The limit of detection for the CALUX assay is currently less than 0.1 fmol (32 fg) TEQ, which corresponds with the amount of TEQs present in 0.1 to 1 ml of blood plasma in environmentally exposed species or man.
Toxic and biochemical effects of 3,3',4,4'-tetrachlorobiphenyl (CB-77) and Clophen A50 on eider ducklings (Somateria mollissima) in a semi-field experiment. Murk, A.J.; van den Berg, J.H.H.; Fellinger, M.; Rozemeijer, M.J.C.; Swennen, C.; Duiven, P.; Boon, J.P.; Koeman, J.H. General rightsIt is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright holder(s), other than for strictly personal, individual use, unless the work is under an open content license (like Creative Commons). Disclaimer/Complaints regulationsIf you believe that digital publication of certain material infringes any of your rights or (privacy) interests, please let the Library know, stating your reasons. In case of a legitimate complaint, the Library will make the material inaccessible and/or remove it from the website. Please Ask the Library: http://uba.uva.nl/en/contact, or a letter to: Library of the University of Amsterdam, Secretariat, Singel 425, 1012 WP Amsterdam, The Netherlands. You will be contacted as soon as possible.
The Management of Wageningen Marine Research is not responsible for resulting damage, as well as for damage resulting from the application of results or research obtained by Wageningen Marine Research, its clients or any claims related to the application of information found within its research. This report has been made on the request of the client and is wholly the client's property.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.