Realistic human head models are of great interest in traumatic brain injury research and in the forensic pathology courtroom and teaching. Due to a lack of biomechanical data, the human dura mater is underrepresented in head models. This study provides tensile data of 73 fresh human cranial dura mater samples retrieved from an area between the anterior middle and the posterior middle meningeal artery. Tissues were adapted to their native water content using the osmotic stress technique. Tensile tests were conducted under quasi-static uniaxial testing conditions with simultaneous digital image correlation. Human temporal dura mater is mechanically highly variable with regards to its elastic modulus of 70 ± 44 MPa, tensile strength of 7 ± 4 MPa, and maximum strain of 11 ± 3 percent. Mechanical properties of the dura mater did not vary significantly between side nor sex and decreased with the age of the cadaver. Both elastic modulus and tensile strength appear to have constant mechanical parameters within the first 139 hours post mortem. The mechanical properties provided by this study can help to improve computational and physical human head models. These properties under quasi-static conditions do not require adjustments for side nor sex, whereas adjustments of tensile properties accompanied with normal aging may be of interest.
Three-dimensional (3D) printing has become broadly available and can be utilized to customize clamping mechanisms in biomechanical experiments. This report will describe our experience using 3D printed clamps to mount soft tissues from different anatomical regions. The feasibility and potential limitations of the technology will be discussed. Tissues were sourced in a fresh condition, including human skin, ligaments and tendons. Standardized clamps and fixtures were 3D printed and used to mount specimens. In quasi-static tensile tests combined with digital image correlation and fatigue trials we characterized the applicability of the clamping technique. Scanning electron microscopy was utilized to evaluate the specimens to assess the integrity of the extracellular matrix following the mechanical tests. 3D printed clamps showed no signs of clamping-related failure during the quasi-static tests, and intact extracellular matrix was found in the clamping area, at the transition clamping area and the central area from where the strain data was obtained. In the fatigue tests, material slippage was low, allowing for cyclic tests beyond 105 cycles. Comparison to other clamping techniques yields that 3D printed clamps ease and expedite specimen handling, are highly adaptable to specimen geometries and ideal for high-standardization and high-throughput experiments in soft tissue biomechanics.
Though it is known that the water content of biological soft tissues alters mechanical properties, little attempt has been made to adjust the tissue water content prior to biomechanical testing as part of standardization procedures. The objective of this study was to examine the effects of altered water content on the macro and micro scale mechanical tissues properties. Human iliotibial band samples were obtained during autopsies to osmotically adapt their water content. Macro mechanical tensile testing of the samples was conducted with digital image correlation, and micro mechanical tests using atomic force microscopy. Analyses were conducted for elastic moduli, tensile strength, and strain at maximum force, and correlations for water content, anthropometric data, and post-mortem interval. Different mechanical properties exist at different water concentrations. Correlations to anthropometric data are more likely to be found at water concentrations close to the native state. These data underline the need for adapting the water content of soft tissues for macro and micro biomechanical experiments to optimize their validity. The osmotic stress protocol provides a feasible and reliable standardization approach to adjust for water content-related differences induced by age at death, post-mortem interval and tissue processing time with known impact on the stress-strain properties.
Thiel embalming is a well-known method of anatomical fixation giving lifelike optical and haptic tissue properties. Beyond these characteristics, Thiel embalming may also be a promising method to provide lifelike tissues for validation purposes of human head biomechanics. Recent investigations using Thielembalmed human tissues of the upper and lower limb yielded contradicting biomechanical results on fixation-induced changes in the tissues' load-deformation behavior. It is to date unclear if Thiel embalming may have a softening or stiffening effect on human soft tissues or no global effect on biomechanics compared to the fresh state, with the latter being the most desirable outcome. The given study aimed at assessing the effects of Thiel embalming on the uniaxial tensile properties of human head soft tissues. Age-matched fresh and Thiel-embalmed dura mater, temporalis muscle, temporalis muscle fascia, and scalp samples were examined. Dura, fascia, and scalp samples showed significantly different elastic moduli compared to fresh tissues (all P < 0.01). The observed ultimate tensile strength supports the theory of an increased collagen crosslinking of the embalmed tissues when compared to the fresh state. Thiel-embalmed muscles failed any tensile testing approach as a result of the muscles dissolving due to the embalming. Furthermore, collagen integrity seems altered in scanning electron microscopy by the Thiel embalming, limiting their use for ultrastructural failure analyses. Thiel-embalmed soft tissues may consequently not serve to reflect the biomechanical properties of the human head. Consequently, the application of Thiel embalming should be limited to preliminary tests for biomechanical purposes. Clin. Anat. 32:903-913, 2019.
The sacroiliac joint (SIJ) is a well-known source of low back and pelvic pain, of increasing interest for both conservative and surgical treatment. Alterations in the kinematics of the pelvis have been hypothesized as a major cause of SIJ-related pain. However, definitions of both the range and the extent of physiological movement are controversial, and there are no clear baseline data for pathological alterations. The present study combined a novel biomechanical setup allowing for physiological motion of the lumbosacral transition and pelvis without restricting the SIJ movement in vitro, combined with optical image correlation. Six fresh human pelvises (81 AE 10 years, three females, three males) were tested, with bodyweight-adapted loading applied to the fifth lumbar vertebra and both acetabula. Deformation at the lumbopelvises was determined computationally from three-dimensional image correlation data. Sacroiliac joint motion under the loading of 100% bodyweight primarily consisted of a z-axis rotation (0.16°) and an inferior translation of the sacrum relative to the ilium (0.32 mm). Sacroiliac joint flexion-extension rotations were minute (< 0.02°). Corresponding movements of the SIJ were found at the lumbosacral transition, with an anterior translation of L5 relative to the sacrum of À0.97 mm and an inferior translation of 0.11 mm, respectively. Moreover, a flexion of 1.82°was observed at the lumbosacral transition. Within the innominate bone and at the pubic symphysis, small complementary rotations were seen around a vertical axis, accounting for À0.10°and 0.11°, respectively. Other motions were minute and accompanied by large interindividual variation. The present study provides evidence of different SIJ motions than reported previously when exerted by physiological loading. Sacroiliac joint kinematics were in the sub-degree and sub-millimeter range, in line with previous in vivo and in vitro findings, largely limited to the sagittal rotation and an inferior translation of the sacrum relative to the ilium. This given physiological loading scenario underlines the relevance of the lumbosacral transition when considering the overall motion of the lumbopelvis, and how relatively little the other segments contribute to overall motion.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.