We present a 16 × 16 CMOS biosensor array aiming at impedance detection of whole-cell bacteria. Each 14 μm × 16 μm pixel comprises high-sensitive passivated microelectrodes connected to an innovative readout interface based on charge sharing principle for capacitance-to-voltage conversion and subthreshold gain stage to boost the sensitivity. Fabricated in a 0.25 μm CMOS process, the capacitive array was experimentally shown to perform accurate dielectric measurements of the electrolyte up to electrical conductivities of 0.05 S/m, with maximal sensitivity of 55 mV/fF and signal-to-noise ratio (SNR) of 37 dB. As biosensing proof of concept, real-time detection of Staphylococcus epidermidis binding events was experimentally demonstrated and provides detection limit of ca. 7 bacteria per pixel and sensitivity of 2.18 mV per bacterial cell. Models and simulations show good matching with experimental results and provide a comprehensive analysis of the sensor and circuit system. Advantages, challenges and limits of the proposed capacitive biosensor array are finally described with regards to literature. With its small area and low power consumption, the present capacitive array is particularly suitable for portable point-of-care (PoC) diagnosis tools and lab-on-chip (LoC) systems.
We present the co-integration of CMOS-compatible Al/Al2O3 interdigitated microelectrodes (IDEs) with an electrokinetic-driven macroelectrode for sensitive detection of whole-cell bacteria in a microfluidic channel. Two frequency ranges applied to the macroelectrode were identified to notably increase the bacterial coverage of the impedimetric sensor per unit time. Around 10 kHz, the bacterial cells were directed towards the IDE center thanks to AC electroosmosis (AC-EO) and the sensor capacitance linearly increased, achieving a limit of detection (LoD) of 3.5 × 10(5) CFU mL(-1) after an incubation time of 20 min with Staphylococcus epidermidis. At 63 MHz precisely, a resonance effect due to the device was found to dramatically increase the trapping of S. epidermidis on the sensor periphery, due to the combined actions of short-range contactless dielectrophoresis (cDEP) and long-range Joule heating electrothermal (J-ET) flow. Thanks to a flow-based method, the bacterial cells were redirected towards the sensor center and an LoD of 10(5) CFU mL(-1) was achieved within 20 min of incubation, which is almost two orders of magnitude better than the impedimetric sensor alone. Analytical models and 2D simulations using the Maxwell stress tensor (MST) provide a comprehensive analysis of the experimental results, especially about the spectral balance between cDEP, AC-EO and J-ET accounting for the 33-nm thick insulating layer atop the electrodes. Electrode CMOS compatibility confers portability, miniaturization and affordability capabilities for building point-of-care (PoC) diagnostic tests in a lab-on-a-chip (LoC).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.