Optimization of dry deposition velocity calculation has been of great interest. Every time, determining the value of the concentration boundary layer (CBL) thickness led to a waste of numerical calculation time, which appears as a huge time in large-scale climate models. The goal of this study is to optimize the numerical calculation time in the three-layer deposition model for smooth surfaces through the development of a MATLAB code that can parameterize the appropriate concentration boundary layer height (y+cbl) and internal integral calculation intervals for each particle diameter Dp (0.01–100 µm) and friction velocity u* (0.01–100 m/s). The particle concentration, as a solution to the particle flux equation, is obtained and modeled numerically by performing the left Riemann sum using MATLAB software. On the other hand, the number of subdivisions N of the Riemann sum was also parameterized for each Dp and u* in order to lessen the numerical calculation time. From a numerical point of view, the new parameterizations were tested by several computers; about 78% on the average of the computation time was saved when compared with the original algorithm. In other words, on average, about 1.2 s/calculation was gained, which is valuable in climate models simulations when millions of dry deposition calculations are needed.
In Jordan, ~61% of total residential energy consumption is consumed by heating spaces using portable kerosene (K) and liquified petroleum gas (LPG) heaters. Here, we evaluated the indoor air quality (IAQ) versus the use of K and LPG heaters inside a test room reflecting the typical conditions of Jordanian dwellings during the winter season. The experimental setup included particle size distribution (diameter 0.01–25 µm) measurements, and we utilized a simple sectional indoor aerosol model (SIAM) to estimate the emission rate and lifetime of the combustion products in the test room. The particle number (PN) concentration during the LPG operation was 6 × 104–5.9 × 105 cm−3, depending on the setting at minimum, medium, or maximum. The K heater operation increased with the PN concentrations to a range of 4 × 105–8 × 105 cm−3. On average, the particle losses were 0.7–1.6 h−1 for micron particles (1–10 µm) and 0.8–0.9 h−1 for ultrafine particles (<0.1 µm). The emission rate from the LPG heater was 1.2 × 1010–2.8 × 1010 particles/s (6.6 × 106–8.0 × 106 particles/J), and that for the K heater was about 4.4 × 1010 particles/s (1.9 × 107 particles/J). The results call for the immediate need to apply interventions to improve the IAQ by turning to cleaner heating processes indoors.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.