The objective of this study was to improve the precision of linear energy transfer (LET) measurements using $$\text {Al}_2\text {O}_3\text {:C}$$ Al 2 O 3 :C optically stimulated luminescence detectors (OSLDs) in proton beams, and, with that, improve OSL dosimetry by correcting the readout for the LET-dependent ionization quenching. The OSLDs were irradiated in spot-scanning proton beams at different doses for fluence-averaged LET values in the (0.4–6.5) $$\hbox {keV}\, \upmu \hbox {m}^{-1}$$ keV μ m - 1 range (in water). A commercial automated OSL reader with a built-in beta source was used for the readouts, which enabled a reference irradiation and readout of each OSLD to establish individual corrections. Pulsed OSL was used to separately measure the blue (F-center) and UV ($$F^+$$ F + -center) emission bands of $$\text {Al}_2\text {O}_3\text {:C}$$ Al 2 O 3 :C and the ratio between them (UV/blue signal) was used for the LET measurements. The average deviation between the simulated and measured LET values along the central beam axis amounts to 5.5% if both the dose and LET are varied, but the average deviation is reduced to 3.5% if the OSLDs are irradiated with the same doses. With the measurement procedure and automated equipment used here, the variation in the signals used for LET estimates and quenching-corrections is reduced from 0.9 to 0.6%. The quenching-corrected OSLD doses are in agreement with ionization chamber measurements within the uncertainties. The automated OSLD corrections are demonstrated to improve the LET estimates and the ionization quenching-corrections in proton dosimetry for a clinically relevant energy range up to 230 MeV. It is also for the first time demonstrated how the LET can be estimated for different doses.
Abstract-The present article is an overview of developments and results regarding neutron noise measurements in current mode at the CROCUS zero power facility. Neutron noise measurements offer a non-invasive method to determine kinetic reactor parameters such as the prompt decay constant at criticality α = βeff / Λ, the effective delayed neutron fraction βeff, and the mean generation time Λ for code validation efforts. At higher detection rates, i.e. above 2×10 4 cps in the used configuration at 0.1 W, the previously employed pulse charge amplification electronics with BF3 detectors yielded erroneous results due to dead time effects. Future experimental needs call for higher sensitivity in detectors, higher detection rates or higher reactor powers, and thus a generally more versatile measurement system. We, therefore, explored detectors operated with current mode acquisition electronics to accommodate the need. We approached the matter in two ways: 1) By using the two compensated , also within 1σ agreement. The improvements to previous neutron noise measurements include shorter measurement durations that can achieve comparable statistical uncertainties and measurements at higher detection rates.
An advanced neutron detection system for highly localized measurements in nuclear reactor cores was developed and tested in the Laboratory for Reactor Physics and System Behaviour (LRS) at the École polytechnique fédérale de Lausanne (EPFL), Switzerland, in close collaboration with the Detector group of the Laboratory for Particle Physics (LTP) at the Paul Scherrer Institute (PSI), Switzerland. The miniature-size detector is based on the coupling of a ZnS:6LiF scintillator/converter screen of 1 mm2 and 0.2 mm thickness with a 10-m optical fiber, the latter being connected to a silicon photomultiplier (SiPM). In this development version, the output signal is processed via analog read-out electronics. The present work documents the characterization of a detection system prototype in the mixedradiation fields o f t he C ARROUSEL f acility a nd i ts t esting in the CROCUS zero-power reactor operated at LRS. The fibercoupled scintillator shows a linear response with the reactor power increase up to 6.5 W (i.e. around 108 cm-2s-1 total neutron flux), with a s ubsequent l oss o f l inearity d ue t o e lectronic dead time of the analog system. Nevertheless, the detector shows excellent neutron counting capabilities whether compared to other localized detection systems available at LRS, e.g. miniature fission chambers and an sCVD diamond detector.
The present article presents the mechanical characterization of the fuel rods oscillator developed for the purposes of the COLIBRI experimental program in CROCUS. COLIBRI aims at investigating the radiation noise related to fuel vibrations. The main motivation is the increased amplitudes in the neutron noise distributions recorded in ex- and in-core detectors that have been observed in recent years in Siemens pre-Konvoi type of pressurized water reactors. Several potential explanations have been put forward, but no definitive conclusions could yet be drawn. Among others, changes in fuel assembly or pin vibration patterns, due to recent modifications of assembly structural designs, were pointed out as a possible cause. Computational dynamic tools are currently developed within the Horizon 2020 European project CORTEX, to help with understanding the additional noise amplitude. The COLIBRI program is used for their validation. An in-core device was designed, tested, and licensed between 2015 and 2019 for fuel rods oscillation in CROCUS, in successive steps from out-of-pile tests with dummy fuel rods to critical in-core tests. The characterization of its mechanical behavior is presented, in air and in water, and as a function of the load, for safety and experimental purposes. The device allows simultaneously oscillating up to 18 fuel rods. The maximum oscillation amplitude is 5 mm, while the maximum allowed frequency is 2 Hz, i.e. in the frequency range in which the induced neutron flux fluctuations are most pronounced in nuclear power plants.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.