A pulsed beam of ground state OH radicals is slowed down using a Stark decelerator and is subsequently loaded into an electrostatic trap. Characterization of the molecular beam production, deceleration, and trap loading process is performed via laser induced fluorescence detection inside the quadrupole trap. Depending on the details of the trap loading sequence, typically 10(5) OH (X2Pi(3/2),J=3/2) radicals are trapped at a density of around 10(7) cm(-3) and at temperatures in the 50-500 mK range. The 1/e trap lifetime is around 1.0 s.
Effect of Ti-Al cathode composition on plasma generation and plasma transport in direct current vacuum arc Estimation of electron temperature and density of the decay plasma in a laser-assisted discharge plasma extreme ultraviolet source by using a modified Stark broadening method A magnetized hydrogen plasma beam was generated with a cascaded arc, expanding in a vacuum vessel at an axial magnetic field of up to 1.6 T. Its characteristics were measured at a distance of 4 cm from the nozzle: up to a 2 cm beam diameter, 7.5ϫ 10 20 m −3 electron density, ϳ2 eV electron and ion temperatures, and 3.5 km/ s axial plasma velocity. This gives a 2.6ϫ 10 24 H + m −2 s −1 peak ion flux density, which is unprecedented in linear plasma generators. The high efficiency of the source is obtained by the combined action of the magnetic field and an optimized nozzle geometry. This is interpreted as a cross-field return current that leads to power dissipation in the beam just outside the source.
A highly sensitive imaging Thomson scattering system was developed for low temperature (0.1-10 eV) plasma applications at the Pilot-PSI linear plasma generator. The essential parts of the diagnostic are a neodymium doped yttrium aluminum garnet laser operating at the second harmonic (532 nm), a laser beam line with a unique stray light suppression system and a detection branch consisting of a Littrow spectrometer equipped with an efficient detector based on a "Generation III" image intensifier combined with an intensified charged coupled device camera. The system is capable of measuring electron density and temperature profiles of a plasma column of 30 mm in diameter with a spatial resolution of 0.6 mm and an observational error of 3% in the electron density (n(e)) and 6% in the electron temperature (T(e)) at n(e) = 4 x 10(19) m(-3). This is achievable at an accumulated laser input energy of 11 J (from 30 laser pulses at 10 Hz repetition frequency). The stray light contribution is below 9 x 10(17) m(-3) in electron density equivalents by the application of a unique stray light suppression system. The amount of laser energy that is required for a n(e) and T(e) measurement is 7 x 10(20)n(e) J, which means that single shot measurements are possible for n(e)>2 x 10(21) m(-3).
An advanced Thomson scattering system has been built for a linear plasma generator for plasma surface interaction studies. The Thomson scattering system is based on a Nd:YAG laser operating at the second harmonic and a detection branch featuring a high etendue (f /3) transmission grating spectrometer equipped with an intensified charged coupled device camera. The system is able to measure electron density (n e ) and temperature (T e ) profiles close to the output of the plasma source and, at a distance of 1.25 m, just in front of a target. The detection system enables to measure 50 spatial channels of about 2 mm each, along a laser chord of 95 mm. By summing a total of 30 laser pulses (0.6 J, 10 Hz), an observational error of 3% in n e and 6% in T e (at n e = 9.4 × 10 18 m −3 ) can be obtained. Single pulse Thomson scattering measurements can be performed with the same accuracy for n e > 2.8 × 10 20 m −3 . The minimum measurable density and temperature are n e < 1 × 10 17 m −3and T e < 0.07 eV, respectively. In addition, using the Rayleigh peak, superimposed on the Thomson scattered spectrum, the neutral density (n 0 ) of the plasma can be measured with an accuracy of 25% (at n 0 = 1 × 10 20 m −3 ). In this report, the performance of the Thomson scattering system will be shown along with unprecedented accurate Thomson-Rayleigh scattering measurements on a low-temperature argon plasma expansion into a low-pressure background.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.