A method is described for the analysis of the 16 polycyclic aromatic hydrocarbons (PAHs) prioritized by the USA EPA in meat sausages grilled under common barbecue practices. Quantification was done by GC-MS using perdeuterated internal standards (IS). Validation was done by spiking the matrix at the 0.5 and 1.0 microg/kg levels. The average of expected values ranged from 60 to 134% (median 84%) at the 0.5 microg/kg level and from 69 to 121% (median 96%) at the 1.0 microg/kg level. The median of the limits of detection and quantification were 0.06 and 0.20 microg/kg, respectively, for a 4-g test portion. The carcinogenic PAHs were below the quantification limit in all products except one lamb sausage. Comparison of estimates when either 1, 5, or 16 perdeuterated PAHs were used as IS showed that the most accurate determination of PAHs required that each compound be quantified against its corresponding perdeuterated analogue.
A sensitive and selective isotope dilution liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESIMS/MS) method is presented for the simultaneous analysis of the metabolites of four nitrofuran veterinary drugs, that is, furazolidone, furaltadone, nitrofurantoin, and nitrofurazone, in honey samples. The method entails a combined hydrolysis of protein-bound drug metabolites and derivatization of the resulting metabolites with 2-nitrobenzaldehyde (NBA) during an overnight incubation, followed by a liquid-liquid extraction and a cleanup on a polymeric solid-phase extraction cartridge. Mass spectral acquisition is carried out in the positive ion mode by applying multiple reaction monitoring (MRM) of three diagnostic transition reactions for each analyte under survey. A reliable quantification is obtained by the use of one deuterated analogue per analyte (NBA-d(4) derivative). The method has been validated in honey according to the European Union criteria for the analysis of veterinary drug residues in food. Expressed in underivatized nitrofuran metabolite concentrations, the decision limits (CCalpha) ranged within 0.07-0.46 microg/kg, and the detection capabilities (CCbeta) were within 0.12-0.56 microg/kg. The method has been successfully applied in a survey of honeys of various geographical origins, showing that furazolidone is the main nitrofuran antibiotic administered to treat bacterial diseases of bees.
Two multiresidue methods based on different extraction procedures have been developed and compared for the liquid chromatography electrospray ionization tandem mass spectrometry analysis of 17 mycotoxins including ochratoxin A, aflatoxins (B(1), B(2), G(1), and G(2)), zearalenone, fumonisins (B(1) and B(2)), T-2 toxin, HT-2 toxin, nivalenol, deoxynivalenol, 3- and 15-acetyldeoxynivalenol, fusarenon-X, diacetoxyscirpenol, and neosolaniol in cereal-based commodities. The extraction procedures considered were a QuEChERS-like method and one using accelerated solvent extraction (ASE). Both extraction procedures gave similar performances in terms of linearity (r(2) > 0.98) and precision (both RSD(r) and RSD(iR) < 20%). Trueness was evaluated through participation in four proficiency tests and by the analysis of two certified reference materials and one quality control material. Satisfactory Z scores (|Z| < 2) and trueness values (73-130%) were obtained by the proposed procedures. Limits of quantification were similar by both methods and were within the 1.0-2.0 microg/kg range for aflatoxins, 0.5 microg/kg for ochratoxin A, and the 5-100 microg/kg range for all other mycotoxins tested. The QuEChERS-like method was found to be easier to handle and allowed a higher sample throughput as compared to the ASE method.
Evidence is presented for the first time showing that semicarbazide (SEM) is a minor thermal decomposition product of the blowing agent azodicarbonamide (ADC). A novel direct analytical method based on liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESIMS/MS) has been developed to determine SEM in foamed polyvinyl chloride (PVC) seals of metal lids, as well as in commercially available ADC. The direct LC-MS/MS method for gaskets entails extraction of the gaskets in hot water, addition of ((15)N(2)(13)C)-SEM as internal standard, and injection of an aliquot directly into the LC-MS system, achieving good sensitivity (S/N = 348 for 2 ng injected on-column) and monitoring three characteristic mass transitions (m/z 76-->31; 76 -->44; 76-->59). Semicarbazide can be detected in thermally treated ADC, reaching up to 0.93 mmol mol(-1) at 220 degrees C, as determined by the direct LC-MS/MS method. This new method is also compared to the classical derivatization method using 2-nitrobenzaldehyde (2-NBA) that is routinely employed to determine SEM as an indicator of the usage of the antimicrobial drug nitrofurazone, the use of which is not authorized in the European Union (EU). Both methods revealed proportional results, with approx. 3-fold higher levels recorded by the direct SEM approach, probably due to differences in the extraction procedures used. A limited survey of plastic seals from used press twist and twist-off metal lids on food jars (non-foamed and foamed) revealed levels of SEM ranging from 2 to 8689 microg kg(-1)(average = 1593 microg kg(-1), n= 57 determinations).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.