The biocompatibility and strength retention of a Mg-Ca-Zn alloy were studied to evaluate its efficacy for osteosynthesis applications. Mg-Ca-Zn alloy and self-reinforced poly l-lactide (SR-PLLA) bone screws were implanted into New Zealand rabbits for radiography analysis, micro computed tomography analysis, histomorphometry, hematology, serum biochemistry, histopathology, and inductively coupled plasma mass spectrometry analysis. Bending and torsion tests were performed on intact specimens to find the initial mechanical strength of these Mg-Ca-Zn alloy bone screws. Strength retention of the Mg-Ca-Zn alloy implants were calculated from in vivo degradation rates and initial mechanical strength. Based on the animal study, Mg-Ca-Zn alloy bone screw showed absence of subcutaneous gas pockets, characteristic surface erosion properties, faster degradation rate than SR-PLLA bone screw, normal reference range of hematology and serum biochemistry, better histopathological response than SR-PLLA bone screw, and stable concentrations of each constituent element in soft tissues surrounding the implants. The initial strength and strength retention of Mg-Ca-Zn alloy were compared with those of various biomaterials. The initial strength of Mg-Ca-Zn alloy was higher than those of biostable and biodegradable polymers. The strength retention of Mg-Ca-Zn alloy bone screws was similar to those of biodegradable polymer. Therefore, this Mg-Ca-Zn alloy represents an excellent biodegradable biomaterial candidate for osteosynthesis applications.
BackgroundUse of a baseplate with a smaller diameter in reverse shoulder arthroplasty is increasing, especially in patients with a small glenoid or glenoid wear. However, the effect of a smaller baseplate on stability of the glenoid component has not been evaluated. Thus, the purpose of this study was to determine whether a smaller baseplate (25 mm) is beneficial to the initial stability of the glenoid component compared to that with a baseplate of a commonly used size (29 mm).MethodsMicromotion of glenoid components attached to 14 scapulae of fresh-frozen cadavers was measured and compared between 25- and 29-mm baseplates in biomechanical testing. Impingement-free range of motion in abduction, adduction, internal rotation, and external rotation was evaluated by using a simulated computer model constructed based on the same fresh-frozen cadavers used in biomechanical testing.ResultsMicromotion at the inferior third of the glenoid-glenosphere interface was higher in the 29-mm baseplate group than in the 25-mm baseplate group during both 0.7- and 1-body weight cyclic loading in biomechanical testing. Adduction deficit was smaller, and total impingement-free range of motion from abduction to adduction and rotation were greater in the 25-mm baseplate group than in the 29-mm baseplate group in the simulated computer model.ConclusionsUse of a baseplate with a smaller diameter (25 mm) in reverse shoulder arthroplasty is suitable for improving the primary stability of the glenoid component. With a smaller baseplate, impingement-free range of motion is optimized in a smaller glenoid.Electronic supplementary materialThe online version of this article (doi:10.1186/1471-2474-15-417) contains supplementary material, which is available to authorized users.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.