A miniaturized potentiometric saxitoxin sensor on graphene nanosheets with incorporated lipid films and Anti‐STX, the natural saxitoxin receptor, immobilized on the stabilized lipid films is described in the present paper. An adequate selectivity for detection over a wide range of toxin concentrations, fast response time of ca. 5–20 min, and detection limit of 1 nM have been achieved. The proposed sensor is easy to construct and exhibits good reproducibility, reusability, selectivity, long shelf life and high sensitivity of ca. 60 mV/decade of toxin concentration. The method was implemented and evaluated in lake water and shellfish samples. This novel ultrathin film technology is currently adapted to the rapid detection of other toxins that could be used in bioterrorism.
The present work describes a miniaturized potentiometric naphthalene acetic acid (NAA) sensor on graphene nanosheets with incorporated lipid films. Auxin‐binding protein 1 receptor immobilized on the stabilized lipid films provided adequate selectivity for detection over a wide range of hormone concentrations, fast response time of ca. 5 min, and detection limit of 10 nM. The proposed sensor is easy to construct and exhibits good reproducibility, reusability, selectivity, long shelf life and high sensitivity of ca. 56 mV/decade of hormone concentration. The reliability of the biosensor was successfully evaluated using a wide range of NAA‐spiked fruits and vegetables.
The present article describes a miniaturized potentiometric carbofuran chemical sensor on graphene nanosheets with incorporated lipid films. The graphene electrode was used for the development of a very selective and sensitive chemical sensor for the detection of carbofuran by immobilizing an artificial selective receptor on stabilized lipid films. The artificial receptor was synthesized by transformation of the hydroxyl groups of resorcin[4]arene receptor into phosphoryl groups. This chemical sensor responded for the wide range of carbofuran concentrations with fast response time of ca. 20 s. The presented potentiometric carbofuran chemical sensor is easy to construct and exhibits good reproducibility, reusability, selectivity, rapid response times, long shelf life and high sensitivity of ca. 59 mV/decade over the carbofuran logarithmic concentration range from 10−6 to 10−3 M.
The investigation of lipid films for the construction of biosensors has recently given the opportunity to manufacture devices to selectively detect a wide range of food toxicants, environmental pollutants, and compounds of clinical interest. Biosensor miniaturization using nanotechnological tools has provided novel routes to immobilize various “receptors” within the lipid film. This chapter reviews and exploits platforms in biosensors based on lipid membrane technology that are used in food, environmental, and clinical chemistry to detect various toxicants. Examples of applications are described with an emphasis on novel systems, new sensing techniques, and nanotechnology-based transduction schemes. The compounds that can be monitored are insecticides, pesticides, herbicides, metals, toxins, antibiotics, microorganisms, hormones, dioxins, etc.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.