Objective: A rapid, simple and sensitive RP-HPLC method was developed and validated for the determination of bisoprolol fumarate in bulk and pharmaceutical dosage form. ABSTRACT Methods:Chromatographic separation was achieved within 2.5 min on ACQUITY Arc System, Waters Symmetry C18 column (3.9 mm i.d. X 150 mm, 5 μm particle sizes) using a mobile phase consisted of acetonitrile: phosphate buffer (25:75 v/v) in an isocratic mode at a flow rate of 1.4 ml/min. The pH of the mobile phase was adjusted to 7.0 with orthophosphoric acid and UV detection was set at 226 nm. Results:The retention time for bisoprolol fumarate was found to be 2.09 min. The proposed method was validated according to ICH guidelines with respect to linearity, specificity precision, accuracy and robustness. The limit of detection and limit of quantification are calculated and found to be 0.4825 and 1.4621 μg/ml; respectively. Conclusion:The proposed method can help research studies, quality control and routine analysis with lesser resources available. The results of the assay of pharmaceutical formulation of the developed method are highly reliable and reproducible and is in good agreement with the label claim of the medicines.
Objective: A simple, rapid, economical, and highly sensitive stability-indicating HPLC method was developed and fully validated for determination of enalapril maleate in presence of its related substances namely enalaprilat dihydrate and diketopiperazine.Methods: Chromatographic separation was achieved on Grace Platinumр C8 EPS column (4.6 mm i.d. X 250 mm, 5 μm) at room temperature. The mobile phase consisted of acetonitrile: 20 mmol phosphate buffer adjusted to pH 2.2 (25:75 v/v) isocratically pumped at a flow rate 2 ml/min and UV-detection was monitored at 215 nm.Results: The proposed method was validated according to ICH guidelines with total run time less than 9 min. The correlation coefficient (r2) was noted as 0.99981 which states that the method was good linear to the concentration versus peak area responses. The developed method found to be high sensitivity with LOD and LOQ of 0.021 and 0.062 %; respectively. The developed, validated method was successfully applied for the determination of enalapril maleate in presence of their impurities in tablet dosage form.Conclusion: A rapid, economical, simple and sensitive HPLC method was developed and validated for the determination of enalapril maleate in tablet dosage form in presence of their impurities. The developed method can help research studies, quality control and routine analysis with lesser resources available. Therefore, the proposed validated method is fast and reliable and can be used for routine quantitative analysis as well as quality control of enalapril maleate in pharmaceutical formulation.
Objective: A simple, rapid, and reproducible high-performance liquid chromatography method was developed for the simultaneous determination of amlodipine and valsartan in their combined dosage forms and for drug dissolution studies.Methods: A C 18 column (Zorbax Eclipse ХDB-C18, 5 µm, 2.1 mm × 150 mm) and a mobile phase of water:acetonitrile:trifluoroacetic acid (55:45:0.1 v/v/v) mixture were used for separation and quantification. Analyses were run at a flow rate of 0.4 mL/min and at ambient temperature. The injection volume was 5 µL and the ultraviolet detector was set at 265 nm. The method was validated as per ICH guidelines.Results: Under these conditions, amlodipine and valsartan were eluted at 1.64 min and 4.08 min, respectively. Total run time was shorter than 7 min. The results were 99.6 ± 0.6 and 98.5 ± 0.8 for amlodipine and valsartan, respectively. Valsartan was released within 15 min (98.32%) and amlodipine was also released within 30 min (96.16%) both at a pH of 6.8. Conclusion:The developed method was applied successfully for quality control assay of amlodipine and valsartan in their combination drug product and in vitro dissolution studies.
Objective: The objective of this research was to develop more simple, sensitive, accurate, and less expensive analytical methods for the determination of captopril in medicines by Ultra-high-performance liquid chromatography. Materials and Methods:The chromatographic analysis of captopril performed on liquid chromatography Agilent 1290 Infinity II LC System. Results:A simple, rapid, sensitive, and specific method was developed for the determination of captopril by ultra-high-performance liquid chromatography in mono-medicines and pharmaceutical dosage forms in combination with hydrochlorothiazide without previous separation. Satisfactory resolution was achieved using Fused-Core® technology Ascentis Express C18 column (4.6×150 mm) and a mobile phase consisting of methanol and 0.1% solution of trifluoroacetic acid (40/60, v/v) at a flow rate 1.2 mL/minute and the wavelength detection was 220 nm. Ascentis Express columns, based on Fusеd-core pаrticle technоlogy, prоvide more than twice the speed and efficiency of traditiоnal cоlumns at half the backpressure of sub-2-µm columns. The retention time for captopril was 1.345 minute. The validation of this method was based on the ICH and USP guidelines. Conclusion:The results obtained in this research work clearly indicated that the assay was rapid, sensitive and successfully applied to the determination of both drugs in pharmaceutical dosage forms without interference from tablet excipients.
Our main target was to develop methods for the quality control of the tablet «ramipril» according to the indicators of «Quantitative determination», «Impurities» and «Dissolution». New, precise, accurate and green HPLC methods were developed for the determination of ramipril and its impurities in tablets. The separation was accomplished using a diode array detector at 210 nm with an isocratic and gradient mobile phase consisting of a 0.2 g/L solution of sodium hexanesulfonate (pH 2.7) and the acetonitrile and chromatographic columns Acclaim 120 C18 and Inertsil ODS-3. The developed method was validated in accordance with ICH guidelines. The analysis of impurities was performed within a run duration of less than 25 min, which is about a two times shorter than that of the official Ph. Eur. method. The analysis of ramipril in tablets was performed with a run duration of less than 4.5 min, which is about three times shorter than that of the official USP method. The developed methods were successfully applied for the quality control of the tablet «ramipril» according to the indicators of «Quantitative determination», «Impurities» and «Dissolution». In addition, they proved its superiority over the reported methods in terms of greenness using different assessment tools.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.