2007
DOI: 10.1016/j.chroma.2007.05.012
|View full text |Cite
|
Sign up to set email alerts
|

Aliphatic carboxylic acids as new modifiers for separation of 2,4-dinitrophenyl amino acids by micellar liquid chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2010
2010
2019
2019

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 21 publications
(5 citation statements)
references
References 33 publications
0
5
0
Order By: Relevance
“…Phosphoric acid was used for pH adjustments. It is interesting to note that the two acids and the two corresponding alcohols have the same molar volumes ( Table 2) so mobile phases with equal modifier volume fractions have also equal molar concentrations [31]. …”
Section: Experimental Design and Selection Of Experimental Conditionsmentioning
confidence: 99%
See 2 more Smart Citations
“…Phosphoric acid was used for pH adjustments. It is interesting to note that the two acids and the two corresponding alcohols have the same molar volumes ( Table 2) so mobile phases with equal modifier volume fractions have also equal molar concentrations [31]. …”
Section: Experimental Design and Selection Of Experimental Conditionsmentioning
confidence: 99%
“…The effect of alcohols on the properties of micellar solutions has been extensively studied for years due to usefulness of such systems in microemulsion formation [34]. However, only a limited number of works focused on the effects of short and middle chain carboxylic acids on the properties of micellar solutions [31,32,39,40].…”
Section: Additive Effects On Micellar Solutions Of Sdsmentioning
confidence: 99%
See 1 more Smart Citation
“…8,9 Another important advantage of MLC is the decreasing of silanophilic interactions due to dynamic modification of the stationary phase by adsorption of surfactant monomers. [9][10][11] Recently, Kulikov and Galat 12 have shown that the chromatographic properties of reversed-phase columns are much more similar in the MLC mode than in the RP-HPLC mode. This results in robust separation of analyte mixtures using columns from different manufactures in the MLC mode.…”
Section: Introductionmentioning
confidence: 99%
“…The growing interest in micellar LC (MLC) has resulted in an exponentially increasing production of analytical applications during the past few years 1–5. MLC presents noticeable advantages over conventional LC in the aspects as far as high solubilization capability, direct injection of physiological fluids and unique separation selectivity are concerned.…”
Section: Introductionmentioning
confidence: 99%