2006
DOI: 10.1590/s0100-40422006000400020
|View full text |Cite
|
Sign up to set email alerts
|

Determinação espectrofotométrica simultânea de cobre e ferro em álcool etílico combustível com reagentes derivados da ferroína

Abstract: Recebido em 19/7/05; aceito em 28/9/05; publicado na web em 18/4/06 SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION OF IRON AND COPPER USING FERROIN REAGENTS. In the present work three ferroin reagents were studied for the simultaneous spectrophotometric determination of iron and copper: 1,10-phenanthroline, 2,2'-bipyridine and 2,4,6-tri(2-pyridyl)-1,3,5-triazine. Effect of pH, conditions, order reagent addition, interferences, amount of reagents, lineal range, sensitivity and stability of each system were compa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
10
0
2

Year Published

2009
2009
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 26 publications
(14 citation statements)
references
References 12 publications
1
10
0
2
Order By: Relevance
“…A linear behavior was observed: y = -2.698x -1.673, r = 0.9990, for a range of (2.4 B C Fe(III) B 49.8) lmol L -1 , showing a: 1-good sensitivity, S = 25.1 lA/lmol L -1 ; 2-lower detection limit, LOD = (2.40 ± 0.10) lmol L -1 [42]; and 3-good repeatability, r = 4.0%, for n = 5 [43]. So, these parameter values are in agreement with those shown in the literature [42][43][44][45]. Thus, there are efforts in progress in our laboratory to improve the analytical parameters, applying the more sensitive square wave voltammetry (SWV) technique, and subsequent method validation.…”
Section: Clay Binary Film Investigationsupporting
confidence: 90%
“…A linear behavior was observed: y = -2.698x -1.673, r = 0.9990, for a range of (2.4 B C Fe(III) B 49.8) lmol L -1 , showing a: 1-good sensitivity, S = 25.1 lA/lmol L -1 ; 2-lower detection limit, LOD = (2.40 ± 0.10) lmol L -1 [42]; and 3-good repeatability, r = 4.0%, for n = 5 [43]. So, these parameter values are in agreement with those shown in the literature [42][43][44][45]. Thus, there are efforts in progress in our laboratory to improve the analytical parameters, applying the more sensitive square wave voltammetry (SWV) technique, and subsequent method validation.…”
Section: Clay Binary Film Investigationsupporting
confidence: 90%
“…Estes valores são muito inferiores em relação àqueles estabelecidos pela Resolução nº 36 da Agência Nacional do Petróleo. 40,69 Medidas espectrofotométricas permitem a análise de cobre em amostras de álcool combustível. 70 O procedimento envolve a formação de um complexo, entre o metal e o composto batocuproína, e sua detecção em níveis de concentração de 6,2 g L -1 .…”
Section: Aplicação De Técnicas Espectrofotométricasunclassified
“…The LOD's were similar or lower than those observed by other authors. 2,9,11,35,36 Table 3 also details the optimum linear response range for each metal ion, with each analyte showing good linearity.…”
Section: Analysis Of Fuel Ethanol Samplesmentioning
confidence: 99%