2011
DOI: 10.1021/bc200523p
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical Strategy for Sensing Protein Phosphorylation

Abstract: We herein report a novel electrochemical method in this paper to monitor protein phosphorylation and to assay protein kinase activity based on Zr(4+) mediated signal transition and rolling circle amplification (RCA). First, substrate peptide immobilized on a gold electrode can be phosphorylated by protein kinase A. Then, Zr(4+) links phosphorylated peptide and DNA primer probe by interacting with the phosphate groups. After the introduction of the padlock probe and phi29 DNA polymerase, RCA is achieved on the … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
49
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 80 publications
(49 citation statements)
references
References 30 publications
0
49
0
Order By: Relevance
“…[55][56][57][58][59] Usually, the resulting phosphorylated products could be recognized by the elements such as antiphosphorylated peptide antibodies, 19 metal ions, 20 metal complexes, [21][22][23] and nanoparticles. [24][25][26] Moreover, the use of ATP analogs as the cosubstrates (eg, ferrocene [Fc]-ATP, biotin-ATP, and adenosine 5′-[γ-thio] triphosphate [ATP-S]) can also facilitate the development of various novel electrochemical kinase biosensors. [27][28][29][30][31][32] However, most of these methods require catalyzed phosphorylation reaction to a specific peptide substrate.…”
mentioning
confidence: 99%
“…[55][56][57][58][59] Usually, the resulting phosphorylated products could be recognized by the elements such as antiphosphorylated peptide antibodies, 19 metal ions, 20 metal complexes, [21][22][23] and nanoparticles. [24][25][26] Moreover, the use of ATP analogs as the cosubstrates (eg, ferrocene [Fc]-ATP, biotin-ATP, and adenosine 5′-[γ-thio] triphosphate [ATP-S]) can also facilitate the development of various novel electrochemical kinase biosensors. [27][28][29][30][31][32] However, most of these methods require catalyzed phosphorylation reaction to a specific peptide substrate.…”
mentioning
confidence: 99%
“…The corresponding linear regressions could be expressed as I ¼-20.32 log c þ120.81 (R ¼0.9932). The detection limit was estimated to be 0.047 unit/mL (S/N ¼ 3), which was lower than those of 10 , 0.5 (Miao et al, 2012;Tan et al, 2013), 0.47 (Xu et al, 2011), 0.2 (Ji et al, 2009), 0.15 (Xu et al, 2009), 0.134 (Zhou et al, 2013), 0.1 , 0.07 and 0.061 unit/mL (Xu et al, 2012).…”
Section: Detection Of Ck2 Activity and Inhibitorsmentioning
confidence: 72%
“…The concentration of the ZrOCl 2 solution was adopted based on our previous work [22] as well as optimized in Fig. S2.…”
Section: Insulin Detectionmentioning
confidence: 99%