2021
DOI: 10.1016/j.chaos.2021.110802
|View full text |Cite
|
Sign up to set email alerts
|

Fractal and multifractal analysis of electrochemical noise to corrosion evaluation in A36 steel and AISI 304 stainless steel exposed to MEA-CO2 aqueous solutions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 15 publications
(6 citation statements)
references
References 28 publications
0
5
0
Order By: Relevance
“…The fractality of some copper alloys’ behavior has been investigated in studies related to electrochemical corrosion [ 1 , 2 , 3 , 4 , 5 , 6 , 7 ] and signal analysis [ 18 ]. Also, multifractal analysis of corroded surface images has been performed for different materials [ 38 , 60 , 61 , 62 ]. Still, these studies have been performed using a smaller number of tools, among which are R/S rescaled analysis and MFDFA [ 50 ].…”
Section: Resultsmentioning
confidence: 99%
“…The fractality of some copper alloys’ behavior has been investigated in studies related to electrochemical corrosion [ 1 , 2 , 3 , 4 , 5 , 6 , 7 ] and signal analysis [ 18 ]. Also, multifractal analysis of corroded surface images has been performed for different materials [ 38 , 60 , 61 , 62 ]. Still, these studies have been performed using a smaller number of tools, among which are R/S rescaled analysis and MFDFA [ 50 ].…”
Section: Resultsmentioning
confidence: 99%
“…EN involves measuring the electrochemical transient noise produced by the corrosion process [131,132]. This is accomplished by measuring the potential noise of the potential difference between two identical electrodes or by tracking current differences between two similar electrodes using a zero resistance ammeter [133].…”
Section: Electrochemical Noisementioning
confidence: 99%
“…Recently, aqueous monoethanolamine (MEA) solvent has been investigated for its feasibility for large-scale applications based on efficient energy consumption, removal capacity, and other cost-related studies. In general, aqueous amine solvent is thermally stable, is highly selective, and has greater than 90% CO 2 capture efficiency; however, the corrosion potential of materials coming in contact with the solvent is a major operational concern in amine treatment plants because it may lead to structural integrity issue and failure. For example, carbon steel (e.g., S235) has unacceptable levels of corrosion failure in aqueous MEA . Also, aluminum alloys are corrosion resistant in the atmosphere; however, they often have poor corrosion resistance when they are submerged in aqueous solutions.…”
Section: Introductionmentioning
confidence: 99%
“…For example, carbon steel (e.g., S235) has unacceptable levels of corrosion failure in aqueous MEA. 6 Also, aluminum alloys are corrosion resistant in the atmosphere; however, they often have poor corrosion resistance when they are submerged in aqueous solutions. The aluminum corrosion rates are relatively high when the pH of the chemical stream is either below 4 or above 7.…”
Section: ■ Introductionmentioning
confidence: 99%