“…Table 1 shows that the sensitivities of the proposed sensor have higher curvature sensitivity and temperature sensitivity than those of the PCF-MZI and FBG (4.06 nm/m −1 and 6.3 pm/ ) ℃ [8], and MMF-PCF-MMF inscribed FBG (−1.36 nm/m −1 and 60.3 pm/℃) [9]. However, the sensor we report has lower curvature sensitivity than the four-core fiber multipath MZI (20.18 nm/m −1 ) [28], MMF-TCF(twin core fiber)-MMF (103.35 nm/m −1 ) [30], and MMF-TCSMF-MMF (−28.29 nm/m −1 ) [31], respectively, because TCSMF, TCF, and four-core fiber are a kind of specialty optical fibers with the multi-core structure separately containing only one core mode. The curvature and temperature resolutions of the sensor can be obtained by using the error analysis method when the resolution ( Dip) δ Δ of the OSA is known, and the curvature and temperature resolutions of the sensor can be represented by [32] Dip2, Dip1, Dip2, Dip1,…”