2016
DOI: 10.1016/j.matlet.2016.03.085
|View full text |Cite
|
Sign up to set email alerts
|

Influence of γ radiation on the shear modulus of magnetorheological elastomer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 10 publications
0
4
0
Order By: Relevance
“…The current literature describes the MREs with even larger relative MR effects. However, these effects are achieved due to very low G 0 ′ (1 kPa), 15 which is in most cases undesirable from a practical point of view or due to introducing higher amounts of magnetic particles 34,39 or the application of a higher H (>850 kA m −1 ), 27,39 where the homogeneity of the magnetic field strength and thus performance of such MRE are rather speculative. 28 Further, we discuss the changes of ΔG′, that as was shown recently can be enhanced by the incorporation of higher amounts of the particles 27 and/or by the fabrication of the MREs with different inner structure (iso-and anisotropic).…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
“…The current literature describes the MREs with even larger relative MR effects. However, these effects are achieved due to very low G 0 ′ (1 kPa), 15 which is in most cases undesirable from a practical point of view or due to introducing higher amounts of magnetic particles 34,39 or the application of a higher H (>850 kA m −1 ), 27,39 where the homogeneity of the magnetic field strength and thus performance of such MRE are rather speculative. 28 Further, we discuss the changes of ΔG′, that as was shown recently can be enhanced by the incorporation of higher amounts of the particles 27 and/or by the fabrication of the MREs with different inner structure (iso-and anisotropic).…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
“…Another strategy in enhancing the MR effects is particle grafting with polymers, modifying the particle/matrix interactions [51]. Moreover, in some papers [25,53] high magnetic fields (H > 850 kA m −1…”
Section: Magnetorheological Activitymentioning
confidence: 99%
“…On the other hand, MRE overcomes these issues related to MR fluid however are still characterized by the low MR effect (change in properties in the presence of a magnetic field) [1,3]. But it must be noted that there has been remarkable progress in the field of the MREs both in experiment and modelling in recent years [1][2][3][6][7][8][9][10][11][12][13].…”
Section: Introductionmentioning
confidence: 99%