2008
DOI: 10.3844/ajassp.2008.1318.1321
|View full text |Cite
|
Sign up to set email alerts
|

Simulation Studies on A Cross Flow Plate Fin Heat Exchanger

Abstract: Abstract:Compact heat exchangers which were initially developed for the aerospace industries in the 1940s have been considerably improved in the past few years. The main reasons for the good performance of compact heat exchangers are their special design which includes turbulent which in turn use high heat transfer coefficient and resists fouling, and maximum temperature driving force between the hot and cold fluids. Numerous types use special enhancement techniques to achieve the required heat transfer in sma… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
1
0
5

Year Published

2012
2012
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 6 publications
0
1
0
5
Order By: Relevance
“…Evaluasi dilakukan terhadap nilai koefisien perpindahan panas clean overall (Uc), koefisien perpindahan panas dirty overall (Ud), fouling factor (Rd) dan efisiensi. Solusi dari permasalahan tersebut diharapkan dapat meningkatkan efisiensi perpindahan kalor pada heat exchanger karena terjadinya pengurangan pada energi yang dibutuhkan atau penurunan terhadap ukuran heat exchanger [3].…”
Section: Pendahuluanunclassified
“…Evaluasi dilakukan terhadap nilai koefisien perpindahan panas clean overall (Uc), koefisien perpindahan panas dirty overall (Ud), fouling factor (Rd) dan efisiensi. Solusi dari permasalahan tersebut diharapkan dapat meningkatkan efisiensi perpindahan kalor pada heat exchanger karena terjadinya pengurangan pada energi yang dibutuhkan atau penurunan terhadap ukuran heat exchanger [3].…”
Section: Pendahuluanunclassified
“…Pengembangan terhadap heat exchanger dilakukan dalam upaya untuk mengatasi permasalahan-permasalahan seperti: laju perpindahan kalor, faktor gesekan, pola aliran fluida kerja, jenis material heat exchanger, efektivitas perpindahan kalor, jenis heat exchanger. Solusi dari permasalahan tersebut diharapkan dapat meningkatkan efisiensi perpindahan kalor pada heat exchanger karena terjadinya pengurangan pada energi yang dibutuhkan atau penurunan terhadap ukuran heat exchanger [5]. Pada penelitian Mufid kenaikan flowrate fluida panas mengakibatkan menurunnya Number of Transfer Unit (NTU).…”
Section: Pendahuluanunclassified
“…Pengembangan terhadap heat exchanger dilakukan dalam upaya untuk mengatasi permasalahan-permasalahan seperti: laju perpindahan kalor, faktor gesekan, pola aliran fluida kerja, jenis material heat exchanger, efektifitas perpindahan kalor, jenis heat exchanger. Solusi dari permasalahan tersebut diharapkan dapat meningkatkan efisiensi perpindahan kalor pada heat exchanger karena terjadinya pengurangan pada energi yang dibutuhkan atau penurunan terhadap ukuran heat exchanger [12]. Meningkatnya konveksi paksa akan dapat memperkecil kebutuhan energi dalam mengalirkan fluida kerja ke sistem penukar kalor [2].…”
Section: Pendahuluanunclassified