The level of particulate matter of less than 10 μm diameter (PM10) at subway platforms can be significantly reduced by installing a platform screen-door system. However, both workers and passengers might be exposed to higher PM10 levels while the cars are within the tunnel because it is a more confined environment. This study determined the PM10 levels in a subway tunnel, and identified the sources of PM10 using elemental analysis and receptor modeling. Forty-four PM10 samples were collected in the tunnel between the Gireum and Mia stations on Line 4 in metropolitan Seoul and analyzed using inductively coupled plasma-atomic emission spectrometry and ion chromatography. The major PM10 sources were identified using positive matrix factorization (PMF). The average PM10 concentration in the tunnels was 200.8 ± 22.0 μg/m3. Elemental analysis indicated that the PM10 consisted of 40.4% inorganic species, 9.1% anions, 4.9% cations, and 45.6% other materials. Iron was the most abundant element, with an average concentration of 72.5 ± 10.4 μg/m3. The PM10 sources characterized by PMF included rail, wheel, and brake wear (59.6%), soil combustion (17.0%), secondary aerosols (10.0%), electric cable wear (8.1%), and soil and road dust (5.4%). Internal sources comprising rail, wheel, brake, and electric cable wear made the greatest contribution to the PM10 (67.7%) in tunnel air. Implications: With installation of a platform screen door, PM10 levels in subway tunnels were higher than those on platforms. Tunnel PM10 levels exceeded 150 µg/m3 of the Korean standard for subway platform. Elemental analysis of PM10 in a tunnel showed that Fe was the most abundant element. Five PM10 sources in tunnel were identified by positive matrix factorization. Railroad-related sources contributed 68% of PM10 in the subway tunnel.
This study characterized emissions of particulate matter (PM), volatile organic compounds (VOCs), heavy metals, and anions from Mongolian bituminous coals in a controlled heating experiment. Three coal samples from Alag Tolgoi (coal 1), Baganuur (coal 2), and Nalaikh (coal 3) were combusted at a constant heat flux of 50 kW/m2 using a dual-cone calorimeter. The coal samples were commonly used in ger district of Ulaanbaatar, Mongolia. PM10 emission factors were 1122.9 ± 526.2, 958.1 ± 584.0, and 472.0 ± 57.1 mg/kg for coal samples 1, 2, and 3, respectively. PM with a diameter of 0.35–0.45 µm was dominant and accounted for 41, 34, and 48% of the total PM for coal samples 1, 2, and 3, respectively. The emissions of PM and VOC from coals commonly used in Ulaanbaatar, Mongolia were significant enough to cause extremely high levels of indoor and outdoor air pollution.
Vinyl samples were burned in a controlled environment to determine the characteristics of particulate matter (PM) and volatile organic compound (VOC) emissions during the combustion process. Open burning of plastic or vinyl products poses several environmental and health risks in developed and developing countries, due to the release of high concentrations of harmful pollutants. The production of fine and ultrafine particles was significant. At a heat flux of 25 kW/m2, the production of PM of 0.35 μm in size was highest at 63.0 μg/m3. In comparison, at fluxes of 35 and 50 kW/m2, the production of PM of 0.45 μm in size was highest with values of 67.8 and 87.7 μg/m3, respectively. Benzene, acetone, and other toxic compounds were also identified in the analyses.
Although metal contact is known to reduce bacterial growth, the effects of physical barriers and electricity need further investigation. This study examined the bacteria-reducing properties of copper and stainless-steel metal plates with an added electrical current and up to three filter layers on the growth of Escherichia coli (bacteria) and MS2 bacteriophages (virus). When used with a stainless-steel plate, electricity increased bacteria reduction by 39.5 ± 2.30% in comparison with no electricity added, whereas a three-layer physical barrier decreased its efficiency. Copper also reduced the growth of bacteria, by 58.2 ± 8.23%, and the addition of electricity reduced it further (79.5 ± 2.34%). Bacteriophages were also affected by the metal contact. Further experiments showed that MS2 was also reduced by copper, to 82.9 ± 4.5% after 24 h at 37 °C.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.